SPIRAL WOUND GASKETS

The Garlock EDGE®


Compare

Standard spiral wound gasket shows excessive radial buckling        The patented Garlock EDGE® spiral wound gasket is designed to eliminate radial buckling
The Garlock EDGE


Benefits

No Radial Buckling
  • STABL-LOCK™ inner wrap construction prevents sealing element from flowing into and contaminating process stream
  • Garlock CONTROLLED DENSITY™ winding prevents bolt torque loss and requires less compressive force to seal
Tightest seal
  • Retaining groove grips winding firmly, maintaining symmetrical cross-section for most effective seal
  • Modified guide ring ensures contact with all raised face surfaces
Multiple applications
  • Dual flange (DF) design accommodates both 150 and 300 lb flanges—reduces inventory costs
  • Select from a wide variety of metallic and filler materials with a full range of temperature capabilities



Gasket Style
and Material
"M" "Y"
(psi)
Gb
(psi)
'a' Gs
(psi)
Garlock EDGE®
with 304 stainless and
flexible graphite filler
2.00 5,000 793 0.4 0.31



Dual Flange (DF) Design

Dual Flange (DF) Design


WARNING:
Properties/application shown here are typical. Your specific application should not be undertaken without independent study and evaluation for suitability. For specific application recommendations consult Garlock. Failure to select the proper sealing products could result in property damage and/or serious personal injury.

Performance data published here has been developed from field testing, customer field reports and/or in-house testing.

While the utmost care has been used in compiling this information, we assume no responsibility for errors. Specifications subject to change without notice. This edition cancels all previous issues. Subject to change without notice.


Copyright © Garlock Sealing Technologies

Back to Metallic Gaskets